Schneider 14 -pin Miniature plug-in relay, 6 A, DC with Base Socket - Model RXM4AB1


Volt: 12 V
Price:
Sale priceLE 357.18

Description

Range of product

RXM4AB1BD

RXM4AB1JD

Product or component type

14 -pin Plug-in relay

14 -pin Plug-in relay

Contacts type and composition

4 C/O

4 C/O

[Uc] control circuit voltage

24 V DC

12 V DC

Status LED

Without

Without

Control type

Lockable test button

Lockable test button

Utilisation coefficient

20%

20%

Shape of pin

Flat

Flat

[Ui] rated insulation voltage

250 V conforming to IEC

250 V conforming to IEC

300 V conforming to CSA

300 V conforming to CSA

300 V conforming to UL

300 V conforming to UL

[Uimp] rated impulse withstand voltage

2.5 kV during 1.2/50 µs

2.5 kV during 1.2/50 µs

Contacts material

AgNi

AgNi

[Ie] rated operational current

3 A at 28 V (DC) NC conforming to IEC

3 A at 28 V (DC) NC conforming to IEC

3 A at 250 V (AC) NC conforming to IEC

3 A at 250 V (AC) NC conforming to IEC

6 A at 28 V (DC) NO conforming to IEC

6 A at 28 V (DC) NO conforming to IEC

6 A at 250 V (AC) NO conforming to IEC

6 A at 250 V (AC) NO conforming to IEC

6 A at 277 V (AC) conforming to UL

6 A at 277 V (AC) conforming to UL

8 A at 30 V (DC) conforming to UL

8 A at 30 V (DC) conforming to UL

Continuous output current

5:00 AM

5:00 AM

Maximum switching voltage

250 V conforming to IEC

250 V conforming to IEC

resistive rated load

6 A at 250 V AC

6 A at 250 V AC

6 A at 28 V DC

6 A at 28 V DC

Maximum switching capacity

1500 VA/168 W

1500 VA/168 W

Minimum switching capacity

170 mW at 10 mA, 17 V

170 mW at 10 mA, 17 V

Operating rate

<= 1200 cycles/hour under load

<= 1200 cycles/hour under load

<= 18000 cycles/hour no-load

<= 18000 cycles/hour no-load

Mechanical durability

10000000 cycles

10000000 cycles

Electrical durability

100000 cycles for resistive load

100000 cycles for resistive load

average coil consumption

0.9 W

0.9 W

Drop-out voltage threshold

>= 0.1 Uc

>= 0.1 Uc

operate time

20 ms

20 ms

release time

20 ms

20 ms

average coil resistance

650 Ohm at 20 °C +/- 10 %

160 Ohm at 20 °C +/- 10 %

Rated operational voltage limits

19.2…26.4 V DC

9.6…13.2 V DC

Safety reliability data

B10d = 100000

B10d = 100000

Protection category

RT I

RT I

Test levels

Level A group mounting

Level A group mounting

Operating position

Any position

Any position

CAD overall height

79 mm

79 mm

CAD overall depth

78.45 mm

78.45 mm