{"product_id":"schneider-easypact-cvs-cvs250b-tm200d-circuit-breaker-200-a-3p-3d-lv525302","title":"Schneider Easypact CVS - CVS250B TM200D circuit breaker , 200 A  - 3P\/3d  - LV525302","description":"\u003ctable class=\"specifications-table\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eRange of product\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eEasyPact CVS100...250\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eProduct name\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eEasyPact CVS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eDevice short name\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text\"\u003eCVS250B\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eProduct or component type\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eCircuit breaker\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eDevice application\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eDistribution\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003ePoles description\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e3P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eProtected poles description\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e3D\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eEarth leakage protection (Vigi add on)\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eWithout\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003e[In] rated current\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e200 A at 40 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eNetwork type\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eUtilisation category\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eCategory A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003e[Icu] Breaking capacity\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e40 kA Icu at 220\/240 V AC 50\/60 Hz conforming to IEC 60947-2\u003cbr\u003e25 kA Icu at 380\/415 V AC 50\/60 Hz conforming to IEC 60947-2\u003cbr\u003e20 kA Icu at 440 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eTrip unit name\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eTM-D\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eTrip unit technology\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eThermal-magnetic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eTrip unit rating\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e200 A at 40 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eProtection type\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eShort-circuit protection (magnetic)\u003cbr\u003eOverload protection (thermal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":49835290132720,"sku":"LV525302","price":13899.48,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0611\/0307\/9664\/files\/LV525302-_3_200.jpg?v=1781265916","url":"https:\/\/derhali.com\/en\/products\/schneider-easypact-cvs-cvs250b-tm200d-circuit-breaker-200-a-3p-3d-lv525302","provider":"Derhali","version":"1.0","type":"link"}