Description
Specification |
LC1D09M7 – 9 A |
LC1D12M7 - 12 A |
LC1D18M7 - 18 A |
LC1D25M7 - 25A |
LC1D32M7 - 32 A |
Coil Voltage (Control) |
220 V AC, 50/60 Hz |
||||
Rated Operational Voltage (Ue) |
≤ 690 V AC (25–400 Hz) / ≤ 300 V DC |
||||
Rated Current (Ie) – AC-1 |
25 A (at ≤ 440 V AC, 60 °C) |
25 A (≤ 440 V AC, 60 °C) |
32 A (≤ 440 V AC, 60 °C) |
40 A @ ≤ 440 V AC (≤ 60 °C) |
50 A @ ≤ 440 V AC, 60 °C |
Rated Current (Ie) – AC-3 |
9 A (at ≤ 440 V AC, 60 °C) |
12 A (≤ 440 V AC, 60 °C) |
18 A (≤ 440 V AC, 60 °C) |
25 A @ ≤ 440 V AC (≤ 60 °C) |
32 A @ ≤ 440 V AC, 60 °C |
Motor Power Rating (kW) |
2.2 kW @ 220–230 V • 4 kW @ 380–400 V • 4 kW @ 415–440 V • 5.5 kW @ 500 V • 5.5 kW @ 660–690 V (AC-3) |
3 kW @ 220–230 V • 5.5 kW @ 380–400 V • 5.5 kW @ 415–440 V • 7.5 kW @ 500 V • 7.5 kW @ 660–690 V (all AC-3) |
4 kW @ 220–230 V • 7.5 kW @ 380–400 V • 9 kW @ 415–440 V • 10 kW @ 500 V • 10 kW @ 660–690 V (all AC-3) |
5.5 kW @ 220–230 V • 11 kW @ 380–400 V • 11 kW @ 415–440 V • 15 kW @ 500 V • 15 kW @ 660–690 V |
7.5 kW @ 220–230 V • 15 kW @ 380–400 V • 15 kW @ 415–440 V • 18.5 kW @ 500 V • 18.5 kW @ 660–690 V |
Number of Poles |
3-pole (3 NO main contacts) |
||||
Auxiliary Contacts |
1 NO + 1 NC |
||||
Utilization Category |
AC-1, AC-3, AC-4, AC-3e |
AC-1, AC-3, AC-3e, AC-4 |
AC-1, AC-3, AC-3e, AC-4 |
AC-1, AC-3, AC-4, AC-3e |
AC-1, AC-3, AC-4, AC-3e |
Mechanical Life |
15 million operations |
||||
Electrical Life |
2 million operations @ 9 A AC-3 (≤ 440 V) |
2 million operations @ 12 A AC-3 (≤ 440 V) |
1.65 million operations @ 18 A AC-3 (≤ 440 V) |
1.65 million operations @ 25 A AC-3, ≤ 440 V |
1.65 million operations @ 32 A AC-3 |
Making / Breaking Capacity |
250 A @ 440 V AC |
250 A @ 440 V AC (IEC 60947) |
300 A @ 440 V AC (IEC 60947) |
450 A @ 440 V AC |
550 A @ 440 V AC |
Operating Temperature Range |
–40 … 60 °C (up to 70 °C with derating) |
||||
Rated Insulation Voltage (Ui) |
690 V AC (IEC 60947-4-1) |
||||
Protection Degree (IP) |
IP20 (front face, IEC 60529) |
IP20 (front face) |
|||
Mounting Type |
DIN rail or plate |
||||
Standards / Certifications |
IEC 60947-4-1, IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 14, CCC, UKCA, EAC, Marine, CB Scheme |
IEC 60947-4-1, IEC 60947-5-1, UL, CSA, CCC, UKCA, EAC, CB Scheme, Marine |
IEC 60947-4-1, IEC 60947-5-1, EN 60947-4-1, EN 60947-5-1, UL 508, CSA C22.2 No 14, UKCA, CCC, BV, GL, Lloyd’s Register, DNV, RINA, GOST |
IEC 60947-4-1/5-1, UL 508, CSA C22.2 No 14, EN 60947-4-1/5-1, IEC 60335-1, UKCA, CCC, CB, BV, GL, DNV, RINA, GOST, Lloyd’s Register |