Schneider LC1D contactor – 3Poles 440 V - 220 V AC 50/60 Hz coil ( 40 / 50 / 65 A)


AMP: 50 A
Price:
Sale priceLE 5,267.00

Description

Specification

LC1D40AM7

LC1D50AM7

LC1D65AM7

Coil Voltage (Control)

220 V AC 50/60 Hz

220 V AC 50/60 Hz

220 V AC 50/60 Hz

Rated Operational Voltage (Ue)

Power circuit: ≤ 690 V AC 25–400 Hz / ≤ 300 V DC

Power circuit: ≤ 690 V AC 25–400 Hz / ≤ 300 V DC

Power circuit: ≤ 690 V AC 25–400 Hz / ≤ 300 V DC

Rated Current (Ie) – AC-1

60 A (≤ 440 V AC, < 60 °C)

80 A (≤ 440 V AC, < 60 °C)

80 A (≤ 440 V AC, < 60 °C)

Rated Current (Ie) – AC-3

40 A (≤ 440 V AC, < 60 °C)

50 A (≤ 440 V AC, < 60 °C)

65 A (≤ 440 V AC, < 60 °C)

Motor Power Rating (kW)

18.5 kW at 380–400 V AC 50/60 Hz (AC-3); 11 kW at 220–230 V AC 50/60 Hz (AC-3); 22 kW at 415–440 V AC 50/60 Hz (AC-3); 22 kW at 500 V AC 50/60 Hz (AC-3); 30 kW at 660–690 V AC 50/60 Hz (AC-3)

15 kW at 220–230 V AC 50/60 Hz (AC-3); 22 kW at 380–400 V AC (AC-3); 25 kW at 415 V AC (AC-3); 30 kW at 440 V AC (AC-3); 30 kW at 500 V AC (AC-3); 33 kW at 660–690 V AC (AC-3)

18.5 kW at 220–230 V AC (AC-3); 30 kW at 380–400 V AC (AC-3); 37 kW at 500 V AC (AC-3); 37 kW at 660–690 V AC (AC-3)

Number of Poles

3P

3P

3P

Auxiliary Contacts

1 NO + 1 NC (mechanically linked, mirror contact)

1 NO + 1 NC (mechanically linked, mirror contact)

1 NO + 1 NC (mechanically linked, mirror contact)

Utilization Category

AC-1, AC-3, AC-3e, AC-4

AC-1, AC-3, AC-3e, AC-4

AC-1, AC-3, AC-3e, AC-4

Mechanical Life

6 million operations

6 million operations

6 million operations

Electrical Life

1.4 million operations (60 A AC-1 ≤ 440 V); 1.5 million operations (40 A AC-3 ≤ 440 V)

1.1 million operations (80 A AC-1 ≤ 440 V); 1.45 million operations (50 A AC-3 ≤ 440 V); 1.45 million operations (50 A AC-3e ≤ 440 V)

1.4 million operations (80 A AC-1 ≤ 440 V); 1.45 million operations (65 A AC-3 ≤ 440 V)

Making / Breaking Capacity

800 A at 440 V (Power circuit, IEC 60947)

900 A at 440 V (IEC 60947)

1000 A at 440 V (IEC 60947)

Operating Temperature Range

−40 … 60 °C (up to 70 °C with derating)

−40 … 60 °C (up to 70 °C with derating)

−40 … 60 °C (up to 70 °C with derating)

Rated Insulation Voltage (Ui)

Power circuit: 690 V (IEC 60947-4-1); 600 V (CSA/UL)

690 V (IEC 60947-4-1)

690 V (IEC 60947-4-1); 600 V (CSA/UL)

Protection Degree (IP)

IP20 (front face, IEC 60529)

IP20 (front face, IEC 60529)

IP20 (front face, IEC 60529)

Mounting Type

Plate or Rail

Plate or Rail

Plate or Rail

Standards / Certifications

IEC 60947-4-1, IEC 60947-5-1, EN 60947-4-1, EN 60947-5-1, CSA C22.2 No 14, UL 60947-4-1, IEC 60335-2-40 Annex JJ, UL 60335-2-40 Annex JJ, IEC 60335-1 Clause 30.2; Certifications: CCC, UL, CB Scheme, CSA, CE, UKCA, Marine, EAC

EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, IEC 60335-1/-2-40, UL 60947-4-1, UL 60335-2-40, CSA C22.2 No 14; Certifications: CE, UKCA, CCC, CB Scheme, Marine, EAC

EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, CSA C22.2 No 14, UL 60947-4-1, IEC 60335-2-40 Annex JJ, UL 60335-2-40 Annex JJ, IEC 60335-1 Clause 30.2; Certifications: CCC, UL, CB Scheme, CSA, CE, UKCA, Marine, EAC